clarify return value notes in template

This commit is contained in:
joeycastillo 2023-01-17 11:02:56 -06:00
parent 3142fccea3
commit 45cd1dcac1

View file

@ -81,8 +81,12 @@ bool <#watch_face_name#>_face_loop(movement_event_t event, movement_settings_t *
return movement_default_loop_handler(event, settings);
}
// return true if the watch can enter standby mode. If you are PWM'ing an LED or buzzing the buzzer here,
// you should return false since the PWM driver does not operate in standby mode.
// return true if the watch can enter standby mode. Generally speaking, you should always return true.
// Exceptions:
// * If you are displaying a color using the low-level watch_set_led_color function, you should return false.
// * If you are sounding the buzzer using the low-level watch_set_buzzer_on function, you should return false.
// Note that if you are driving the LED or buzzer using Movement functions like movement_illuminate_led or
// movement_play_alarm, you can still return true. This guidance only applies to the low-level watch_ functions.
return true;
}